1-1-70 Code Restriction Class Assignment
When Lockout is Set
General Description
Use this Memory Block to assign the Code Restriction Class when a station user sets
the Station Outgoing Lockout or when the Attendant sets Attendant Station Outgoing
Lockout.
Display
Related Programming
Refer to Chapter 3 Advanced Applications, Section 1 Code Restriction on page 3-1.
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 +
GK
to access the Memory Block.
3 Used dial pad to enter class restriction.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Default Values
Class 15
4 Press
G
to write selected data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
When a station is locked out, the Code Restriction Class Assignment of this Memory Block is used instead of the
Code Restriction Class assigned in Memory Block 4-07 [Code Restriction Class Assignment (Day Mode)] or 4-08
[Code Restriction Class Assignment (Night Mode)].
System Mode
1
Submode
1
Data No.
70
PC Programming
¦
+AC
Data
No.
7 0 : R E S T C L A S S = 1 5
T I M E D I S P L A Y
Title
Setting
Data

Table of Contents