Elite IPK Document Revision 1
Programming Manual 2 - 133
___________________________________________________________________________________
___________________________________________________________________________________
1-4-03 Automated Attendant No Answer
Disconnect Time Selection
General Description
Use this Memory Block to specify the time the Automated Attendant rings a station
before the caller is automatically disconnected.
Display
Settings
Related Programming
Refer to individual features in the Electra Elite IPK Features and Specifications Manual.
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
1m
2m 3m 4m
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
JC
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
When the called party does not answer in the programmed time, the call is dropped.
System Mode
1
Submode
4
Data No.
03
PC Programming
¦
+AU
0 3 : A A D I S 2 m
T I M E D I S P L A Y
Setting
Data
Title
Data
No.