Elite IPK Document Revision 1
Programming Manual 2 - 11
___________________________________________________________________________________
___________________________________________________________________________________
1-1-07 Tie Line Delay Ringing Time Selection
General Description
Use this Memory Block to specify the time before a Tie line call ringing at a station can
begin ringing at other preassigned stations when it is not answered in a programmed
time. CO/PBX Ringing Assignment defines the preassigned station.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
The shaded
selection is the
default.
10s 20s 30s
(No Limit)
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 +
KG
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-34
Tie Line First Ring Pattern Selection
4-01
CO/PBX Ring Assignment (Day Mode)
4-02
CO/PBX Ring Assignment (Night Mode)
4-12
Line Key Selection for Telephone Mode
System Mode
1
Submode
1
Data No.
07
PC Programming
¦
+ALM
0 7 : T L D L Y R N G
T I M E D I S P L A Y
Setting
Data
Title
Data
No.

Table of Contents