2 - 54 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1 Elite IPK
1-1-49 Networking Trunk Group/Route
Advance Assignment
General Description
Use this Memory Block to assign the function number of the Trunk Group to be used to
network an Electra Elite 48/192 system to another system by Tie lines or CO/PBX/
CTX lines.
Display
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 +
DI
to access the Memory Block.
3 Use dial pad to enter the Function Number for Closed Number Block 01 of the Trunk
Group or the Route Advance Block.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
H
to clear all data
Default Values
Not Specified
4 Press
G
to write selected data and display the next Closed Number Block.
5 Repeat Steps 3 and 4 for each Closed Number Block. After data for the last Closed Number Block is written, the next Memory
Block is displayed.
6 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-30
Route Advance Block Assignment
1-1-50
CO/PBX Outgoing Digit Add Assignment
3-03
Trunk-to-Trunk Group Assignment
Function Number 101
~
132 (Trunk Group 1
~
32, respectively) or 201
~
232 (Route Advance Block 1
~
32,
respectively) is assigned to Closed Number blocks.
System Mode
1
Submode
1
Data No.
49
PC Programming
¦
+BCS
Data
No.
4 9 : 0 1 = R T
T I M E D I S P L A Y
Closed
Number
Block
01~16
Function
No.