2 - 400 Programming Manual
___________________________________________________________________________________
Document Revison 1 Elite IPK
___________________________________________________________________________________
3-20 Tie Line Loop Off-Guard Time
Selection
General Description
Use this Memory Block to assign loop off-guard time to prevent noise that could cause
the system to be unable to answer an incoming Tie line.
Display
Settings
Page 1
LK 1 LK 2 LK 3 LK 4
LK 5 LK 6 LK 7 LK 8
The shaded
selection is the
default. Times
are in seconds.
0.0 0.5 1.0 1.5
2.0 3.0 4.0. 5.0
Page 2
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0
Programming Procedures
1 Go off-line.
2 Press LK3 +
G
+
BK
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change loop off-guard time for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D
to go to the next assigned CO/PBX No.
C
to go to the next page.
A
to go to the previous page.
4 Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
CO/PBX Line Mod