Elite IPK Document Revision 1
Programming Manual 3 - 347
___________________________________________________________________________________
___________________________________________________________________________________
1-16-07 High Priority RX Tag Assignment
General Description
Use this Memory Block to specify a Receive Tag Priority for each port of the
HUB(8)-U( ) ETU.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK16 +
KG
to access the Memory Block.
3 Use dial pad keys to enter Setting data.
Use the following to enter data:
Use
J
to move cursor left
Use
L
to move cursor right
Use
K
~
I
to enter numeric data
Priority range is lowest 0~7 highest.
Default Values
:
All ports = 7
4
Press
G
to write the data.
5
Repeat steps 3 and 4 for each HUB(8)-U( )
ETU
port.
6 Press
E
to go back on-line.
System Mode
1
Submode
16
Data No.
07
PC Programming
¦
+AB
0 7 : 1 - 1 H I G H R X = 7
T I M E D I S P L A Y
Data
No.
Setting
Data
Title
PORT
1~8
HUB
1~3