1-16-17 Back Pressure for Half Duplex
General Description
Use this Memory Block to specify whether or not Back Pressure Flow Control is
enabled for each HUB(8)-U( ) ETU port.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
NO YS
Programming Procedures
1 Go off-line.
2 Press LK1 + LK16 +
AG
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the option.
4 Press
G
to write the data.
5 Repeat steps 3 and 4 for each HUB(8)-U( ) ETU port.
6 Press
E
to go back on-line.
System Mode
1
Submode
16
Data No.
17
PC Programming
¦
+AB
1 7 : 1 - 1 B A C K N O
T I M E D I S P L A Y
Data
No.
Setting
Data
Title
PORT
1~8
HUB
1~3

Table of Contents