3-21 Tie Line Length of Wink Signal
Selection
General Description
Use this Memory Block to specify the time a wink pulse is sent to another system.
Display
Settings
Page 1
LK 1 LK 2 LK 3 LK 4 LK 5
LK 6 LK 7 LK 8
The shaded
selection is the
default. Times
are in
milliseconds.
30 60 90 120 150
180 210 240
Page 2
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
270 300 330 360 390 420 450 480
Programming Procedures
1 Go off-line.
2 Press LK3 +
G
+
BA
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change wink-signal time for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D
to go to the next assigned CO/PBX No.
C
to go to the next page.
A
to go to the previous page.
4 Press
G
to write the data and display the next Memory Block.
CO/PBX Line Mode
3
Submode
—
Data No.
21
PC Programming
¦
+ALM
0 1 / 2 1 : W I N K 1 8 0 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Page
Setting
Data
Wink Pulse Sending
Incoming Signal Detection
Time
DC Loop Supervision
Receiving Side