1-2-30 PS Out of Area Time Assignment
General Description
Use this Memory Block to specify the retry time when a PS II is Out of Area.
Display
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 + LK2 +
CK
to access the Memory Block.
3
Enter data using the dial pad.
Use the following to enter data:
J
t
o move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Default Values
08 seconds
4 Press
G
to write data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
1. When the PS Out of Area time is shorter than the Call Forward-No Answer time, the caller receives an Out of
Area indication.
2. This Memory Block is used to define the Time a system searches for a PS II before displaying Out of Area or
providing a busy tone to the Caller.
3. When using Call Forward - Busy/No Answer feature, verify that the time is compatible with this Memory Block.
System Mode
1
Submode
2
Data No.
30
PC Programming
¦
+AP
3 0 : O U T T I M E R 0 8 s
T I M E D I S P L A Y
Setting Data
Data 00~99
Title
Data
No.