1-16-03 MDI/MDIX Mode Selection
General Description
Use this Memory Block to specify an MDI/MDIX mode for each port of each
HUB(8)-U( ) ETU.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
MDIX MDI
Auto
Programming Procedures
1 Go off-line.
2 Press LK1 + LK16 +
KC
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the Setting Data option.
4 Press
G
to write the data.
5 Repeat steps 3 and 4 for each Port of each HUB(8)-U( ) ETU.
6 Press
E
to go back on-line.
System Mode
1
Submode
16
Data No.
03
PC Programming
¦
+AB
0 3 : 1 - 1 M O D E A U T O
T I M E D I S P L A Y
Data
No.
Setting
Data
Title
PORT
1~8
HUB
1~3