1-3-01 Bounce Protect Time Selection
General Description
Use this Memory Block to specify a time for detection of a valid 0ff-hook indication that
is long enough to prevent an unintentional bounce of the receiver from being detected
as a new off-hook indication from a Single Line Telephone or Voice Mail system.
Display
Settings
Page 1
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
The shaded
selection is the
default.
0ms 100ms 200ms
300ms 400ms 500ms 600ms 700ms
Page 2
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
800ms 900ms 1000ms 1100ms 1200ms 1300ms 1400ms 1500ms
Programming Procedures
1 Go off-line.
2 Press LK1 + LK3 to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-3-05
Hookflash Start Time Selection
System Mode
1
Submode
3
Data No.
01
PC Programming
¦
+BTI
0 1 : B N C E 3 0 0 m s | 1