2 - 176 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1 Elite IPK
1-7-07 External Ring Relay Pattern Selection
General Description
Use this Memory Block to assign a distinctive ringing control/interval pattern to relay
circuits.
Display
Settings
Notes
LK 1 LK 2 LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
PT1 PT2
PT3 PT4
PT5 PT6 PT7
(Continuous
Programming Procedures
1 Go off-line.
2 Press L1 + LK7 +
KG
to access the Memory Block.
3
Press corresponding CO/PBX line key to change the data option.
Use dial pad keys 1~4 to specify external ring relay.
4 Press
G
to write the data.
5 Repeat Steps 3 and 4 for each of the four Ring Relays. The next Memory Block is displayed.
6 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-2-00
Internal Paging Timeout Selection
1-7-02
External Speaker Connection Selection
2-08
ECR Relay to Tenant Assignment
An External Tone relay or the Night Chime relay must be assigned in Memory Block 2-08 (ECR Relay to Tenant
Assignment) before the tone is generated.
System Mode
1
Submode
7
Data No.
07
PC Programming
¦
+BP
0 7 : E X T R I N G 1 = P T 3
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
Ext
Ring
Relay
(1~4)