Electra Elite IPK Document Revision 1
Programming Manual 2 - 107
___________________________________________________________________________________
___________________________________________________________________________________
1-2-21 PS Telephone Block Assignment
General Description
Use this Memory Block to specify the number of PS II stations that can be used in the
system.
Display
Settings
Page 1 Ports 01~32
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
Default: No PS
Telephone
Blocks are
assigned.
Port 01~04 Port 05~08 Port 09~12 Port 13~16 Port 17~20 Port 21~24 Port 25~28 Port 29~32
Page 2 Ports 33~64
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
Port 33~36 Port 37~40 Port 41~44 Port 45~48 Port 49~52 Port 53~56 Port 57~60 Port 61~64
Page 3 Ports 65~96
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
Port 65~68 Port 69~72 Port 73~76 Port 77~80 Port 81~84 Port 85~88 Port 89~92 Port 93~96
Page 4 Ports 97~C0
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
Port 97~A0 Port A1~A4 Port A5~A8 Port A9~B2 Port B3~B6 Port B7~C0
Programming Procedures
1 Go off-line.
2
Press LK1 + LK2 +
BA
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
LK is green = block assigned for PS
LK is red = block not available for PS
Press
C
to cycle between pages.
Setting Data indicates the first port number on the applicable page.
Default Values
No PS Terminal Blocks are assigned.
Hardware equipped ports are red.
4 Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
2
Data No.
21
PC Programming
¦
+AP
2 1 : P H S A S S I G N | 0 1
T I M E D I S P L A Y
Setting
Data
Title
Data
No.