General Description
Use this Memory Block to determine the number of digits for station numbers. Either
2-digit (00~99), 3-digit (000~999), or 4-digit (0000~9999) assignment is available.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
2DGT
3DGT 4DGT
Programming Procedures
1 Go off-line.
2
Press LK1 + LK2 +
KC
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-46
Access Code (1-Digit) Assignment
1-1-47
Access Code (2-Digit) Assignment
4-10
Station Number Assignment
1. The Station Numbering Plan can be 2, 3, or 4 digits; however, only one plan can be used at a time.
2. After a change is made in this Memory Block, all station numbers must be reassigned in Memory Block 4-10
(Station Number Assignment).
System Mode
1
Submode
2
Data No.
03
PC Programming
¦
+BS
0 3 : S T A . N O . 3 D G T
T I M E D I S P L A Y
Setting
Data
Title
Data
No.