Elite IPK Document Revision 1
Programming Manual 2 - 251
___________________________________________________________________________________
___________________________________________________________________________________
1-10-09 Call by Call Simulated Facility Group
Assignment
General Description
Use this Memory Block to specify the Simulated Facility Group (SFG) for each Route
Advance Block (RAB).
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK10 +
JI
to access the Memory Block.
3 Enter data using the dial pad.
Use the following to enter data:
J
and
L
to move the cursor
K
~
I
to enter data
D
to select next RAB No.
Setting Data = 00 (Not Specified)
= 01~16
Default Values
All RABs 00
4 Press
G
to write the data. The next RAB for Memory Block 1-10-00 is displayed. After data for RAB 32 is entered, SFG 1
for Memory Block 1-10-20 is displayed.
5 Program Memory Block 1-10-20 or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
3-03
Trunk-to-Trunk Group Assignment
1-1-30
Route Advance Block Assignment
1-1-46, 47, 48
Access Code (1-, 2-, or 3-Digit) Assignment
1-10-00
Call by Call Type of Network ID Assignment
1-10-01
Call by Call ID Plan Assignment
1-10-02
Call by Call Type of Number Assignment
1-10-03
Call by Call Numbering Plan ID Assignment
1-10-04
Call by Call Network ID Assignment
System Mode
1
Submode
10
Data No.
09
PC Programming
¦
+AY
0 1 / 0 9 : S F G = 0 0
T I M E D I S P L A Y
Data
No.
Setting Data
00~16
RAB
01~32
Title

Table of Contents