___________________________________________________________________________________
1-13-02 Clear Channel Selection
General Description
Use this Memory Block to specify the clear channel selection. When the Zero Byte
Time channel is available, the CLKG-U( ) Unit cannot extract a clock signal from the
PRT trunk. The PRT trunk modifies the Zero Byte Time channel to extract a clock
signal for the CLKG-U( ) Unit.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
ZCS
B8ZS
Programming Procedures
1 Go off-line.
2 Press LK1 + LK13 +
KB
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G
to write the data. The next Memory Block is displayed.
5 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-13-00
PRT Channel Assignment
1-13-01
PRT Signal Format Selection
System Mode
1
Submode
13
Data No.
02
PC Programming
¦
+AN
0 1 / 0 2 : O B Y T E = B 8 Z S
T I M E D I S P L A Y
Data
No.
Setting
Data
PRT
1~8