2 - 538 Memory Blocks
___________________________________________________________________________________
Document Revison 1 Elite IPK
___________________________________________________________________________________
4-91 Telephone Ringing Variation
Selection
General Description
Use this Memory Block to assign a Low, Medium, or High ringing tone frequency when
Telephone is specified in Memory Block 1-1-28 (Distinctive Ringing by Telephone or
CO Selection).
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
MLH
Programming Procedures
1 Go off-line.
2 Press LK4 +
IA
to access the Memory Block.
3
Press the line Key to select ringing frequency for Tel Port No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or Tel Port No.
– OR –
D
to go to next assigned Tel Port No.
B
+
A
to enter A for Port Numbers 100~109
B
+
B
to enter B for Port Numbers 110~119
B
+
C
to enter C for Port Number 120
4 Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-28
Distinctive Ringing by Telephone or CO Selection
3-07
CO/PBX Ringing Variation Selection
Telephone Mode
4
Submode
Data No.
91
PC Programming
¦
+BTM
Data
No.
0 1 / 9 1 : R N G T O N E = M
T I M E D I S P L A Y
Title
Tel
Port
No.
(01
~
C0)
Setting
Data

Table of Contents