Elite IPK Document Revision 1
Programming Manual 3 - 47
___________________________________________________________________________________
___________________________________________________________________________________
3.7.9 Local Operator Call ā Dial 9 +0
LCR search sequence: Dial 0 of International/Operator Table 1ā
RAB 09ā TG 02 ā CO 23.
SETUP Message
3.8 Service Conditions
The following service conditions apply.
H
The Electra Elite supports the AT&T 5ESS-2000 switch, Software
release 5E12 or later using the National ISDN PRI version only.
H
Caller ID is displayed as with normal CO calls.
H
LCR is necessary for Call by Call origination.
H
For an outgoing call to an external line, dialed digits are sent collectively
when the specified ISDN interdigit dialing interval (MB 1-1-81, ISDN Dial
Interval Time Selection, 4 sec default) from the last digit expires. When a
digit is not dialed after seizure of the external line before the interdigit
interval times out, the external line is released and a Busy Tone is
generated.
H
When Call forward Off-premise is assigned, MB 4-47 (ISDN Directory
Number Selection) follows the specification at the TEL to which the call
is forwarded.
H
No tandem connection is allowed in Tie Trunk Mode.
H
For PRI trunks, CO or DID type should be assigned using MB 3-91
(Trunk Type Selection).
H
When PRT is used as an outgoing trunk on Automatic Trunk-to-Trunk
transfer, Caller ID follows the MB 3-52 (ISDN Trunk Directory Number
selection) setting. When allowed, Caller ID is sent to the network.
H
For an incoming call, the lowest numbered channel in the PRT trunk is
used.
H
Call by Call does not follow Tenant Day/Night Mode switching.
CPN NSF
RAB TN NPI TNI NIP NID
F/S
FCV
Service FCV Feature FCV
Service
Parameter
09 0(U) 0(U) No Digits None None None S MEGACOM
Operator
(Local)