– 103 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
BASIC SERVICE FEATURES
08
: Initial Data
BASIC SERVICE FEATURE SETTING DATA
212 When a caller encounters all ACD/UCD stations busy 0
1
Busy Tone is to be sent out
Caller is placed into queuing mode
213 Method to cancel Call Forwarding-All Calls/-Busy Line/-Don’t
Answer (No Answer)
0
1
Feature access code + Feature key
Feature access code + “*” key
214 When a ACD/UCD station dials ACD/UCD Busy out code after
holding the call from a Tie Line/CCSA line on Consultation
Hold
See CM17 Y=6
0
1
ACD/UCD station hears Service Set
Tone, and returns to the call by Switch
Hook Flash
The call is disconnected ACD/UCD
station hears ROT
215 When a ACD/UCD station dials ACD/UCD Busy out code after
holding the call from C.O. Line (DDD/FX/WATS) on Consulta-
tion Hold
See CM17 Y=5
0
1
ACD/UCD station hears Service Set
Tone, and returns to the call by Switch
Hook Flash
The call is disconnected ACD/UCD
station hears ROT
216 Processor for Authorization Code/Forced Account Code 0
1
To provide (MP)
See CM2A Y=00-14, A0
Not provided (OAI)
217 Processor for Remote Access to System (DISA) Code 0
1
To provide (MP)
See CM2A Y=00-14, A0
Not provided (OAI)
220 Burst tone for Operator Monitoring
[Australia Only]
0
1
Only Once
Every 4 seconds
221 Tone sent to all parties on three party conference
NOTE: Setting data 0 is effective only when CM31 Y=0>0 is
04.
0
1
Tone is not sent
Every 4 seconds
Continued on next page