C-8 Parameter Specification Tables
DC590+ Series DC Digital Drive
Tag Mn MMI Block Name MMI Parameter Name Minimum Maximum Default Units Range Notes
187 f7 5703 IN RAW INPUT 0.00 0.00 0.00 % V0 W4
189 f9 5703 IN SCALED INPUT 0.00 0.00 0.00 % V0 W4
191 fb FIELD CONTROL BEMF FBK LEAD 20 5000 100 V0 W0
192 fc FIELD CONTROL BEMF FBK LAG 20 5000 100 V0 W0
195 ff DIGITAL OUTPUT 1 THRESHOLD (>) -300.00 300.00 0.00 % V0 W0
196 fg DIGITAL OUTPUT 2 THRESHOLD (>) -300.00 300.00 0.00 % V0 W0
197 fh DIGITAL OUTPUT 3 THRESHOLD (>) -300.00 300.00 0.00 % V0 W0
198 fi COMMS PORT 3 BAUD RATE 0 9 5
0: 300
1: 600
2: 1200
3: 2400
4: 4800
5: 9600
6: 19200
7: 38400
8: 57600
9: 115200
V0 W0
201 fl CURRENT LOOP REGEN ENABLE 0 1 1
0: 2Q (NON-REGEN)
1: 4Q (REGEN)
V0 W1
202 fm SPEED LOOP INT. DEFEAT 0 1 0
0: OFF
1: ON
V1 W0
203 fn INVERSE TIME INVERSE TIME O/P 0.00 0.00 0.00 % V1 W4
206 fq ENCODER 1 ENCODER 0 0 0 RPM V0 W4
207 fr FEEDBACKS SPEED FEEDBACK 0.00 0.00 0.00 % V0 W4
208 fs SETPOINT SUM 1 RATIO 0 -3.0000 3.0000 1.0000 V0 W0
209 ft FIELD CONTROL FLD.CTRL MODE 0 1 0
0: VOLTAGE CONTROL
1: CURRENT CONTROL
V0 W1
210 fu FIELD CONTROL FLD.VOLTS RATIO 0.0 100.0 90.0 % V0 W0
212 fw JOG/SLACK OPERATING MODE 0 7 0
0: STOP
1: STOP
2: JOG SP. 1
3: JOG SP. 2
4: RUN
5: TAKE UP SP. 1
6: TAKE UP SP. 2
7: CRAWL
V1 W4
216 g0 STOP RATES PROG STOP LIMIT 0.0 600.0 60.0 s V1 W0