Ethernet 8-31 
AC30 series Variable Speed Inverters 
Peer to Peer Parameter Summary 
Note: The value of the Peer to Peer configuration parameters only become active when the Peer to Peer module initialises, i.e. on inverter power-
up or transition of the parameter 1725 Peer to Peer Enable to TRUE. 
Parameter Name  No.  Path  Default  Range  Units  Writable 
Peer to Peer Enable 
172
5 
Setup::Communications::Peer 
to Peer Parameters::Base 
Comms::Peer to Peer 
FALSE  FALSE 
TRUE 
  ALWAYS 
  Peer to Peer Parameter. 
Enables the Peer to Peer module. 
Destination IP Address 
6 
Setup::Communications::Peer 
to Peer Parameters::Base 
Comms::Peer to Peer 
255 
255.255.255.255 
Sets the destination IP address of the data when the Peer to Peer module is sending.  If the Destination 
IP Address is set to 255.255.255.255 then the sent data is broadcast and all listening inverters will 
Destination Port 
7 
Setup::Communications::Peer 
to Peer Parameters::Base 
Comms::Peer to Peer 
65535 
Sets the UDP port number the Peer to Peer module sends data to.  Normally this will be set the same as 
the Local Port. 
Local Port 
172
8 
Setup::Communications::Peer 
to Peer Parameters::Base 
Comms::Peer to Peer 
1250  1 to 
65535 
  ALWAYS