C-62 Parameter Reference
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Indicates the health of the drive configuration. When the drive configuration includes a mutually conflicting requirement, this parameter
indicates the problem; for example, it attempting to run in Closed Loop Vector control mode when no feedback option is configured.
Product Code Flags
1551
Parameters::Device Manager::Drive info
NEVER
Manufacturing flags byte read from the power electronics stack.
Bit 0 When set, indicates that the dynamic brake switch power electronics is fitted. On larger frame sizes the brake switch is a
factory fit option. On frames C,D,E,F and G this bit is ignored.
Bit 1 – 7 Reserved
Manufacturing Flags
1636
Parameters::Device Manager::Drive info
NEVER
Manufacturing flags word read from the control module.
Bit 0 When set, indicates that the drive is a special build.
Bits 1 15 Reserved
OEM ID
1256
Parameters::Device Manager::Drive info
NEVER
A 16-bit integer set in the factory, that identifies the equipment manufacturer. This may be used to lock or tailor an application to a
given manufacturer. To obtain a unique ID apply to Parker Hannifin Electomechanical Drives Business Unit.