EasyManua.ls Logo

Parker AC30 series - Page 254

Parker AC30 series
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C-72 Parameter Reference
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Heatsink Temperature
0407
Same as PNO 393
x.x
-25.0 to 200.0
°C
NEVER
Power stack heatsink temperature in
o
Centigrade.
Elec Rotor Speed
0408
Parameters::Motor Control::Feedbacks
x.x
-1500.0 to 1500.0
Hz
NEVER
Mechanical speed (shaft speed in
rev
/
s
) x number of motor pole pairs. This parameter is not filtered.

Table of Contents

Other manuals for Parker AC30 series

Related product manuals