C-238 Parameter Reference
AC30 series Variable Speed Drive
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
0215
ControlNet MAC ID
Setup::Communications::Option
Parameters::Option Comms::ControlNet
USINT
0
0 to 99
CONFIG
TECHNICIAN
7,4
00957
0216
CNet Producing Inst
Same as PNO 215
WORD
0064
CONFIG
TECHNICIAN
4
00959
0217
CNet Consuming Inst
Same as PNO 215
WORD
0096
CONFIG
TECHNICIAN
4
00961
0218
DeviceNet State
Monitor::Communications::Option
Parameters::Option Comms::DeviceNet
USINT
(enum)
Same as PNO 214
NEVER
OPERATOR
4
00963
0219
DeviceNet MAC ID
Setup::Communications::Option
Parameters::Option Comms::DeviceNet
USINT
0
0 to 63
CONFIG
TECHNICIAN
7,4
00965
0220
DeviceNet Baud Rate
Same as PNO 219
USINT
(enum)
3
0:125 KBPS
1:250 KBPS
2:500 KBPS
3:AUTO
CONFIG
TECHNICIAN
4
00967
0221
DeviceNet Actual Baud
Same as PNO 218
USINT
(enum)
Same as PNO 220
NEVER
OPERATOR
4
00969
0222
DNet Producing Inst
Same as PNO 219
WORD
0064
CONFIG
TECHNICIAN
4
00971
0223
DNet Consuming Inst
Same as PNO 219
WORD
0096
CONFIG
TECHNICIAN
4
00973
0224
EtherCAT State
Monitor::Communications::Option
Parameters::Option Comms::EtherCAT
USINT
(enum)
0:SETUP
1:NW INIT
2:INIT OR PREOP
3:SAFE OPERATIONAL
4:OPERATIONAL
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
NEVER
OPERATOR
4
00975
0225
EtherNet IP State
Monitor::Communications::Option
Parameters::Option Comms::EtherNet IP
USINT
(enum)
Same as PNO 214
NEVER
OPERATOR
4
00977
0226
ENet Producing Inst
Setup::Communications::Option
Parameters::Option Comms::EtherNet IP
WORD
0064
CONFIG
TECHNICIAN
4
00979
0227
ENet Consuming Inst
Same as PNO 226
WORD
0096
CONFIG
TECHNICIAN
4
00981
0228
Modbus RTU State
Monitor::Communications::Option
Parameters::Option Comms::Modbus RTU
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
4
00983
0229
Modbus Device Address
Setup::Communications::Option
Parameters::Option Comms::Modbus RTU
USINT
1
1 to 247
CONFIG
TECHNICIAN
7,4
00985
0230
Modbus RTU Baud Rate
Same as PNO 229
USINT
(enum)
4
0:1200 BPS
1:2400 BPS
2:4800 BPS
3:9600 BPS
4:19200 BPS
5:38400 BPS
6:57600 BPS
7:76800 BPS
8:115200 BPS
CONFIG
TECHNICIAN
4
00987
0231
Parity And Stop Bits
Same as PNO 229
USINT
(enum)
0
0:EVEN, 1 STOP
1:ODD, 1 STOP
2:NONE, 2 STOP
3:NONE, 1 STOP
CONFIG
TECHNICIAN
4
00989
0232
High Word First RTU
Same as PNO 229
BOOL
FALSE
CONFIG
TECHNICIAN
4
00991
0233
Modbus RTU Timeout
Same as PNO 229
TIME
3.000
0.000 to 65.000
s
CONFIG
TECHNICIAN
4
00993
0234
Modbus TCP State
Monitor::Communications::Option
Parameters::Option Comms::Modbus TCP
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
4
00995
0235
High Word First TCP
Setup::Communications::Option
Parameters::Option Comms::Modbus TCP
BOOL
FALSE
CONFIG
TECHNICIAN
4
00997
0236
Modbus TCP Timeout
Same as PNO 235
TIME
3.000
0.000 to 65.000
s
CONFIG
TECHNICIAN
4
00999
0237
Profibus State
Monitor::Communications::Option
Parameters::Option Comms::Profibus
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
4
01001
0238
Profibus Node Address
Setup::Communications::Option
Parameters::Option Comms::Profibus
USINT
0
0 to 126
CONFIG
TECHNICIAN
7,4
01003
0239
PROFINET State
Monitor::Communications::Option
Parameters::Option Comms::PROFINET IO
USINT
(enum)
0:SETUP
1:NW INIT
2:WAITING TO CONNECT
3:STOP MODE
4:CONNECTED
5:ERROR
6:RESERVED
NEVER
OPERATOR
4
01005