Parameter Reference C-239
AC30 series Variable Speed Drive
7:EXCEPTION
8:NONE
0240
PROFINET Device Name
Same as PNO 239
STRING[32]
NEVER
OPERATOR
4
01007
0249
Braking Enable
Parameters::Motor Control::Braking
BOOL
TRUE
ALWAYS
TECHNICIAN
6
01025
0251
Brake Resistance
Parameters::Motor Control::Braking
REAL
100.00
0.01 to 1000.00
Ohm
STOPPED
TECHNICIAN
6
01029
0252
Brake Rated Power
Parameters::Motor Control::Braking
REAL
0.11
0.10 to 510.00
kW
STOPPED
TECHNICIAN
6
01031
0253
Brake Overrating
Parameters::Motor Control::Braking
REAL
25.00
1.00 to 40.00
STOPPED
ENGINEER
6
01033
0254
Braking Active
Parameters::Motor Control::Braking
BOOL
NEVER
TECHNICIAN
01035
0255
Autotune Enable
Setup::Motor Control::Autotune
Parameters::Motor Control::Autotune
BOOL
FALSE
STOPPED
TECHNICIAN
2,4
01037
0256
Autotune Mode
Same as PNO 255
USINT
(enum)
1
0:STATIONARY
1:ROTATING
STOPPED
TECHNICIAN
6,4
01039
0257
Autotune Test Disable
Same as PNO 255
WORD
(bitfield)
0000
0:Stator Resistance
1:Leakage Inductance
2:Magnetising Current
3:Rotor Time Constant
4:Encoder Direction
STOPPED
TECHNICIAN
6,4
01041
0258
Autotune Test Disable.Stator Resistance
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6,4
01043
0259
Autotune Test Disable.Leakage Inductance
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6,4
01045
0260
Autotune Test Disable.Magnetising Current
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6,4
01047
0261
Autotune Test Disable.Rotor Time Constant
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6,4
01049
0262
Autotune Test Disable.Encoder Direction
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6,4
01051
0274
Autotune Ramp Time
Same as PNO 255
TIME
10.000
1.000 to 1000.000
s
STOPPED
TECHNICIAN
6,4
01075
0286
MRAS Speed Percent
Parameters::Motor Control::MRAS
REAL
x.xx
Min to Max
%
NEVER
ENGINEER
4
01099
0287
MRAS Speed RPM
Parameters::Motor Control::MRAS
REAL
x.xx
Min to Max
RPM
NEVER
ENGINEER
4
01101
0289
MRAS Field Frequency
Parameters::Motor Control::MRAS
REAL
x.xx
Min to Max
Hz
NEVER
ENGINEER
4
01105
0290
MRAS Torque Percent
Parameters::Motor Control::MRAS
REAL
x.xx
Min to Max
%
NEVER
ENGINEER
4
01107
0291
MRAS Torque
Parameters::Motor Control::MRAS
REAL
x.xx
Min to Max
Nm
NEVER
ENGINEER
4
01109
0305
Current Limit
Setup::Motor Control::Control and Type
Parameters::Motor Control::Current Limit
REAL
150.0
0.0 to 600.0
%
ALWAYS
TECHNICIAN
01137
0307
Regen Limit Enable
Parameters::Motor Control::Current Limit
BOOL
TRUE
ALWAYS
ENGINEER
4
01141
0310
VHz Flying Start Enable
Parameters::Motor Control::Flycatching
BOOL
FALSE
ALWAYS
TECHNICIAN
4
01147
0311
VC Flying Start Enable
Parameters::Motor Control::Flycatching
BOOL
FALSE
ALWAYS
TECHNICIAN
4
01149
0312
Flying Start Mode
Parameters::Motor Control::Flycatching
USINT
(enum)
0
0:ALWAYS
1:TRIP OR POWER UP
2:TRIP
ALWAYS
TECHNICIAN
4
01151
0313
Search Mode
Parameters::Motor Control::Flycatching
USINT
(enum)
0
0:BIDIRECTIONAL
1:UNIDIRECTION
ALWAYS
TECHNICIAN
4
01153
0314
Search Volts
Parameters::Motor Control::Flycatching
REAL
9.0
0.0 to 100.0
%
ALWAYS
TECHNICIAN
6,4
01155
0315
Search Boost
Parameters::Motor Control::Flycatching
REAL
40.0
0.0 to 50.0
%
ALWAYS
TECHNICIAN
6,4
01157
0316
Search Time
Parameters::Motor Control::Flycatching
TIME
5.000
0.100 to 60.000
s
ALWAYS
TECHNICIAN
6,4
01159
0317
Min Search Speed
Parameters::Motor Control::Flycatching
REAL
5
0 to 500
Hz
ALWAYS
TECHNICIAN
4
01161
0318
Flying Reflux Time
Parameters::Motor Control::Flycatching
TIME
3.000
0.100 to 10.000
s
ALWAYS
TECHNICIAN
6,4
01163
0324
DC Inj Deflux Time
Parameters::Motor Control::Inj Braking
TIME
0.500
0.100 to 20.000
s
ALWAYS
TECHNICIAN
6,4
01175
0325
DC Inj Frequency
Parameters::Motor Control::Inj Braking
REAL
9
1 to 500
Hz
ALWAYS
TECHNICIAN
6,4
01177
0326
DC Inj Current Limit
Parameters::Motor Control::Inj Braking
REAL
100.0
50.0 to 150.0
%
ALWAYS
TECHNICIAN
6,4
01179
0327
DC Pulse Time
Parameters::Motor Control::Inj Braking
TIME
2.000
0.000 to 100.000
s
ALWAYS
TECHNICIAN
6,4
01181
0328
Final DC Pulse Time
Parameters::Motor Control::Inj Braking
TIME
1.000
0.000 to 10.000
s
ALWAYS
TECHNICIAN
6,4
01183
0329
DC Current Level
Parameters::Motor Control::Inj Braking
REAL
3.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
6,4
01185
0330
DC Inj Timeout
Parameters::Motor Control::Inj Braking
TIME
90.000
0.000 to 600.000
s
ALWAYS
TECHNICIAN
6,4
01187
0331
DC Inj Base Volts
Parameters::Motor Control::Inj Braking
REAL
100.00
0.00 to 115.47
%
ALWAYS
TECHNICIAN
6,4
01189
0332
100% Mot Current
Parameters::Motor Control::Motor Load
REAL
x.x
0.0 to 10000.0
NEVER
TECHNICIAN
01191
0333
Mot Inv Time Overload
Parameters::Motor Control::Motor Load
REAL
x.
0 to 500
%
NEVER
TECHNICIAN
4
01193
0334
Mot Inv Time Delay
Parameters::Motor Control::Motor Load
TIME
60.000
6.000 to 60.000
s
ALWAYS
TECHNICIAN
6,4
01195
0335
Mot Inv Time Warning
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
4
01197
0336
Mot Inv Time Active
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
4
01199
0337
Mot Inv Time Output %
Parameters::Motor Control::Motor Load
REAL
x.x
0.0 to 600.0
%
NEVER
TECHNICIAN
4
01201
0338
Mot I2T TC
Parameters::Motor Control::Motor Load
TIME
0.000 to 1000000.000
s
NEVER
TECHNICIAN
4
01203
0339
Actual Mot I2T Output
Parameters::Motor Control::Motor Load
REAL
x.x
0.0 to 600.0
%
NEVER
TECHNICIAN
4
01205
0340
Mot I2T Active
Parameters::Motor Control::Motor Load
BOOL
NEVER
OPERATOR
4
01207
0341
Mot I2T Warning
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
4
01209
0342
Mot I2T Enable
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
4
01211
0343
100% Stk Current
Parameters::Motor Control::Stack Inv Time
REAL
x.x
0.0 to 10000.0
A
NEVER
TECHNICIAN
01213
0344
Long Overload Level
Parameters::Motor Control::Stack Inv Time
REAL
x.
0 to 200
%
NEVER
TECHNICIAN
01215
0345
Long Overload Time
Parameters::Motor Control::Stack Inv Time
TIME
0.000 to 100000.000
s
NEVER
TECHNICIAN
01217
0346
Short Overload Level
Parameters::Motor Control::Stack Inv Time
REAL
x.
0 to 200
%
NEVER
TECHNICIAN
01219
0347
Short Overload Time
Parameters::Motor Control::Stack Inv Time
TIME
0.000 to 10000.000
s
NEVER
TECHNICIAN
01221