Parameter Reference C-241
AC30 series Variable Speed Drive
0426
VHz User Freq[2]
Parameters::Motor Control::Fluxing VHz
REAL
20.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01379
0427
VHz User Freq[3]
Parameters::Motor Control::Fluxing VHz
REAL
30.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01381
0428
VHz User Freq[4]
Parameters::Motor Control::Fluxing VHz
REAL
40.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01383
0429
VHz User Freq[5]
Parameters::Motor Control::Fluxing VHz
REAL
50.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01385
0430
VHz User Freq[6]
Parameters::Motor Control::Fluxing VHz
REAL
60.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01387
0431
VHz User Freq[7]
Parameters::Motor Control::Fluxing VHz
REAL
70.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01389
0432
VHz User Freq[8]
Parameters::Motor Control::Fluxing VHz
REAL
80.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01391
0433
VHz User Freq[9]
Parameters::Motor Control::Fluxing VHz
REAL
90.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01393
0434
VHz User Freq[10]
Parameters::Motor Control::Fluxing VHz
REAL
100.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01395
0435
VHz User Volts
Parameters::Motor Control::Fluxing VHz
ARRAY[0..10]
STOPPED
ENGINEER
01397
0436
VHz User Volts[0]
Parameters::Motor Control::Fluxing VHz
REAL
0.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01399
0437
VHz User Volts[1]
Parameters::Motor Control::Fluxing VHz
REAL
10.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01401
0438
VHz User Volts[2]
Parameters::Motor Control::Fluxing VHz
REAL
20.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01403
0439
VHz User Volts[3]
Parameters::Motor Control::Fluxing VHz
REAL
30.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01405
0440
VHz User Volts[4]
Parameters::Motor Control::Fluxing VHz
REAL
40.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01407
0441
VHz User Volts[5]
Parameters::Motor Control::Fluxing VHz
REAL
50.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01409
0442
VHz User Volts[6]
Parameters::Motor Control::Fluxing VHz
REAL
60.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01411
0443
VHz User Volts[7]
Parameters::Motor Control::Fluxing VHz
REAL
70.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01413
0444
VHz User Volts[8]
Parameters::Motor Control::Fluxing VHz
REAL
80.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01415
0445
VHz User Volts[9]
Parameters::Motor Control::Fluxing VHz
REAL
90.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01417
0446
VHz User Volts[10]
Parameters::Motor Control::Fluxing VHz
REAL
100.0
0.0 to 100.0
%
STOPPED
ENGINEER
4
01419
0447
Fixed Boost
Same as PNO 422
REAL
0.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
6,4
01421
0448
Auto Boost
Parameters::Motor Control::Fluxing VHz
REAL
0.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
6,4
01423
0450
Acceleration Boost
Parameters::Motor Control::Fluxing VHz
REAL
0.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
4
01427
0451
Energy Saving Enable
Parameters::Motor Control::Fluxing VHz
BOOL
FALSE
ALWAYS
TECHNICIAN
4
01429
0453
Vsd Demand
Parameters::Motor Control::Fluxing VHz
REAL
x.x
Min to Max
%
NEVER
TECHNICIAN
4
01433
0454
Vsq Demand
Parameters::Motor Control::Fluxing VHz
REAL
x.x
Min to Max
%
NEVER
TECHNICIAN
4
01435
0455
Rated Motor Current
Setup::Motor Control::Motor Nameplate
Parameters::Motor Control::Motor Nameplate
REAL
1.56
0.00 to 10000.00
A
STOPPED
TECHNICIAN
6,4
01437
0456
Base Voltage
Same as PNO 455
REAL
400.00
0.00 to 1000.00
V
STOPPED
TECHNICIAN
6,4
01439
0457
Base Frequency
Same as PNO 455
REAL
50.00
0.00 to 1000.00
Hz
STOPPED
TECHNICIAN
6,4
01441
0458
Motor Poles
Same as PNO 455
INT
4,
2 to 1000
STOPPED
TECHNICIAN
6,4
01443
0459
Nameplate Speed
Same as PNO 455
REAL
1450.00
0.00 to 100000.00
RPM
STOPPED
TECHNICIAN
6,4
01445
0460
Motor Power
Same as PNO 455
REAL
0.75
0.00 to 3000.00
kW
STOPPED
TECHNICIAN
6,4
01447
0461
Power Factor
Same as PNO 455
REAL
0.71
0.00 to 1.00
STOPPED
TECHNICIAN
6,4
01449
0464
100% Speed in RPM
Setup::Motor Control::Control and Type
Parameters::Motor Control::Scale Setpoint
REAL
1500.0
0.0 to 100000.0
RPM
ALWAYS
TECHNICIAN
01455
0465
Speed Demand RPM
Parameters::Motor Control::Scale Setpoint
REAL
x.x
0.0 to 100000.0
RPM
NEVER
TECHNICIAN
01457
0466
Speed Demand Hz
Parameters::Motor Control::Scale Setpoint
REAL
x.x
0.0 to 60000.0
Hz
NEVER
TECHNICIAN
01459
0467
PMAC SVC Auto Values
Parameters::Motor Control::PMAC SVC
BOOL
TRUE
ALWAYS
TECHNICIAN
6,4
01461
0468
PMAC SVC LPF Speed Hz
Parameters::Motor Control::PMAC SVC
REAL
60.00
0.00 to 10000.00
Hz
ALWAYS
TECHNICIAN
6,4
01463
0469
PMAC SVC P Gain
Parameters::Motor Control::PMAC SVC
REAL
2.42
0.00 to 10000.00
ALWAYS
TECHNICIAN
6,4
01465
0470
PMAC SVC I Gain Hz
Parameters::Motor Control::PMAC SVC
REAL
20.00
0.00 to 10000.00
Hz
ALWAYS
TECHNICIAN
6,4
01467
0476
PMAC SVC Open Loop Strt
Parameters::Motor Control::PMAC SVC
BOOL
TRUE
ALWAYS
TECHNICIAN
4
01479
0477
PMAC SVC Start Time
Parameters::Motor Control::PMAC SVC
TIME
0.500
0.000 to 1000.000
s
ALWAYS
TECHNICIAN
4
01481
0478
PMAC SVC Start Cur
Setup::Motor Control::SVC PMAC
Parameters::Motor Control::PMAC SVC
REAL
10.0
0.0 to 600.0
%
ALWAYS
TECHNICIAN
4
01483
0479
PMAC SVC Start Speed
Same as PNO 478
REAL
5
0 to 200
%
ALWAYS
TECHNICIAN
4
01485
0484
Seq Stop Method VHz
Setup::Motor Control::Control and Type
Parameters::Motor Control::Ramp
USINT
(enum)
1
0:DISABLED VOLTAGE
1:RAMP
2:STOP RAMP
3:DC INJECTION
ALWAYS
TECHNICIAN
4
01495
0485
Ramp Type
Parameters::Motor Control::Ramp
USINT
(enum)
0
0:LINEAR
1:S RAMP
ALWAYS
TECHNICIAN
01497
0486
Acceleration Time
Same as PNO 484
TIME
10.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
6
01499
0487
Deceleration Time
Same as PNO 484
TIME
10.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
6
01501
0488
Symmetric Mode
Parameters::Motor Control::Ramp
BOOL
FALSE
ALWAYS
TECHNICIAN
6
01503
0489
Symmetric Time
Parameters::Motor Control::Ramp
TIME
10.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
01505
0490
Sramp Continuous
Parameters::Motor Control::Ramp
BOOL
FALSE
ALWAYS
TECHNICIAN
01507
0491
Sramp Acceleration
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s²
ALWAYS
OPERATOR
01509
0492
Sramp Deceleration
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s²
ALWAYS
TECHNICIAN
01511
0493
Sramp Jerk 1
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01513
0494
Sramp Jerk 2
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01515
0495
Sramp Jerk 3
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01517
0496
Sramp Jerk 4
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01519
0497
Ramp Hold
Parameters::Motor Control::Ramp
BOOL
FALSE
ALWAYS
TECHNICIAN
01521
0498
Ramping Active
Parameters::Motor Control::Ramp
BOOL
NEVER
TECHNICIAN
01523

Table of Contents