Command reference
R&S
®
ZNL/ZNLE
928User Manual 1178.5966.02 ─ 20
Usage: Setting only
Manual operation: See "Connector / Gender" on page 484
[SENSe<Ch>:]CORRection:DATA:PARameter<Sfk>? [<SfkSettingType>[, <Index>]]
Gets the settings of the active system error correction (or of the factory calibration, if no
channel calibration is active).
Suffix:
<Ch>
.
Number of the calibrated channel.
<Sfk> Number of the system error correction.
Must be omitted or set to 1.
Query parameters:
<SfkSettingType> ACAL | STARt | STOP | POINts | SPOWer | STYPe |
BANDwidth | PDLY | RATTenuation | TYPE | PORTs | SPORt |
THRoughs | TSTamp | LTSTamp | TVNA | MVNA | MTESt |
CKIT | FSMode
The requested setting.
If no <SfkSettingType> is specified, the values for STARt, STOP,
POINts, SPOWer and STYPe are returned
ACAL
1 for automatic calibrations, 0 for manual calibrations
STARt
Start frequency (or CW frequency, if no frequency sweep is
active)
STOP
Stop frequency (or CW frequency, if no frequency sweep is
active)
POINts
Number of points
SPOWer
Source power
STYPe
Sweep type or grid (LIN, LOG, SEGM)
BANDwidth
Measurement bandwidth
PDLY
Point delay (Meas Delay) for OSM
RATTenuation
Receiver attenuations: comma-separated list containing a value
pair <port no.>,<rec. att.> (float,integer) for each of the involved
PORTs
TYPE
Calibration type (see <Type> parameter in [SENSe<Ch>:
]CORRection:COLLect[:ACQuire]:SELected
on page 897)
VNA command reference