Command reference
R&S
®
ZNL/ZNLE
897User Manual 1178.5966.02 ─ 20
[SENSe<Ch>:]CORRection:COLLect[:ACQuire]:SELected................................................. 897
[SENSe<Ch>:]CORRection:COLLect:AUTO..................................................................... 899
[SENSe:]CORRection:COLLect:AUTO:CKIT.....................................................................900
[SENSe:]CORRection:COLLect:AUTO:CKIT:PASSword.....................................................901
[SENSe:]CORRection:COLLect:AUTO:CKIT:PORTs.......................................................... 902
[SENSe:]CORRection:COLLect:AUTO:CKIT:PORTs:ADD.................................................. 902
[SENSe<Ch>:]CORRection:COLLect:AUTO:CONFigure....................................................903
[SENSe<Ch>:]CORRection:COLLect:AUTO:PORTs.......................................................... 904
[SENSe:]CORRection:COLLect:AUTO:PORTs:CONNection?............................................. 905
[SENSe<Ch>:]CORRection:COLLect:AUTO:PORTs:TYPE.................................................906
[SENSe<Ch>:]CORRection:COLLect:AUTO:REPeat......................................................... 907
[SENSe<Ch>:]CORRection:COLLect:AUTO:TEMPcomp................................................... 907
[SENSe<Ch>:]CORRection:COLLect:AUTO:TYPE............................................................908
[SENSe<Ch>:]CORRection:COLLect:AUTO:UTHRough.................................................... 909
[SENSe:]CORRection:COLLect:AVERage........................................................................ 909
[SENSe:]CORRection:COLLect:CHANnels:ALL................................................................ 909
[SENSe:]CORRection:COLLect:CHANnels:MCTYpes........................................................ 909
[SENSe<Ch>:]CORRection:COLLect:CKIT:INSTall............................................................ 911
[SENSe<Ch>:]CORRection:COLLect:CKIT:LOAD..............................................................911
[SENSe<Ch>:]CORRection:COLLect:CKIT:PORT<PhyPt>?............................................... 912
[SENSe<Ch>:]CORRection:COLLect:CONNection<PhyPt>................................................912
[SENSe<Ch>:]CORRection:COLLect:CONNection:GENDers............................................. 913
[SENSe<Ch>:]CORRection:COLLect:CONNection:PORTs.................................................914
[SENSe<Ch>:]CORRection:COLLect:DELete................................................................... 914
[SENSe<Ch>:]CORRection:COLLect:DISCard..................................................................915
[SENSe<Ch>:]CORRection:COLLect:FIXTure[:ACQuire]....................................................915
[SENSe<Ch>:]CORRection:COLLect:FIXTure:EXPort....................................................... 916
[SENSe<Ch>:]CORRection:COLLect:FIXTure:IMPort........................................................ 916
[SENSe:]CORRection:COLLect:FIXTure:LMParameter[:STATe].......................................... 917
[SENSe:]CORRection:COLLect:FIXTure:LMParameter:LOSS[:STATe].................................918
[SENSe<Ch>:]CORRection:COLLect:FIXTure:SAVE......................................................... 918
[SENSe<Ch>:]CORRection:COLLect:FIXTure:STARt........................................................ 918
[SENSe<Ch>:]CORRection:COLLect:LOAD:SELected...................................................... 919
[SENSe<Ch>:]CORRection:COLLect:METHod:DEFine......................................................920
[SENSe<Ch>:]CORRection:COLLect:SAVE:SELected:DEFault.......................................... 921
[SENSe<Ch>:]CORRection:COLLect:SAVE:SELected[:DUMMy]........................................ 922
[SENSe<Ch>:]CORRection:COLLect:SCONnection<PhyPt>..............................................923
[SENSe<Ch>:]CORRection:COLLect[:ACQuire]:SELected <Type>, <TestPort>[,
<SecondPortOrAdapter>[, <Dispersion>[, <DelayTimePhase>]]]
Starts the acquisition of measurement data for the selected standard and port(s). The
standards are reflection or transmission standards and can be connected to arbitrary
analyzer ports.
Note:
●
The calibration measurement has a variable timeout: Timeout = (Sweep time /
Number of sweep points) * 3 + 0.1 s
The timeout may be reached e.g. while the measurement waits for the specified
trigger event. It is used for all standard measurements).
VNA command reference