Remote Control
R&S
®
FSVA/FSV
680Operating Manual 1176.7510.02 ─ 09
Parameters:
<State> ON | OFF
*RST: OFF
Example:
CALC:MARK:FUNC:BPOW:STAT ON
Manual operation: See "Band Power On/Off" on page 295
CALCulate<n>:MARKer<m>:FUNCtion:CENTer
This command matches the center frequency to the frequency of a marker.
If you use the command in combination with a delta marker, that delta marker is turned
into a normal marker.
Suffix:
<n>
.
Selects the measurement window.
<m> Selects the marker.
Example:
CALC:MARK2:FUNC:CENT
Sets the center frequency to the frequency of marker 2.
Manual operation: See "Center =Mkr Freq (span > 0)" on page 302
CALCulate<n>:MARKer<m>:FUNCtion:CSTep
This command matches the center frequency step size to the current marker fre-
quency.
The command turns delta markers into normal markers.
Suffix:
<n>
.
Selects the measurement window.
<m> Selects the marker.
Example:
CALC:MARK3:FUNC:CST
Sets the center frequency to the same value as the frequency of
marker 3.
Usage: Event
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation:CONTinuous <State>
This command turns continuous demodulation of the signal at the marker position in
the frequency domain on and off.
Thus acoustic monitoring of the signals can be performed.
In the time domain continuous demodulation is always on.
This command is only available if the R&S FSVA/FSV option B3 (Audio Demodulator)
is installed.
Remote Control – Commands