EasyManua.ls Logo

Rohde & Schwarz FSVA - Page 302

Rohde & Schwarz FSVA
1106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instrument Functions
R&S
®
FSVA/FSV
302Operating Manual 1176.7510.02 ─ 09
Search Lim Off..............................................................................................304
Next Mode...................................................................................................................304
Exclude LO..................................................................................................................304
Search Mode (Spectrograms).....................................................................................305
Search Mode for Next Peak in X Direction................................................... 305
Search Mode for Next Peak in Y Direction................................................... 305
Marker Search Type..................................................................................... 306
Marker Search Area......................................................................................306
Peak Excursion........................................................................................................... 306
Select Marker (No)
Opens a submenu to select one of 16 markers and define whether the marker is a nor-
mal or a delta marker (see "Marker 1 / Marker 2 / Marker 3 / … Marker 16,/ Marker
Norm/Delta" on page 280). "(No)" indicates the number of the currently active marker.
Peak
Sets the active marker/delta marker to the highest maximum of the trace.
Remote command:
CALCulate<n>:MARKer<m>:MAXimum[:PEAK] on page 667
CALCulate<n>:DELTamarker<m>:MAXimum[:PEAK] on page 621
Next Peak
Sets the active marker/delta marker to the next maximum of the selected trace.
Remote command:
CALCulate<n>:MARKer<m>:MAXimum:NEXT on page 668
CALCulate<n>:DELTamarker<m>:MAXimum:NEXT on page 622
Center =Mkr Freq (span > 0)
Sets the center frequency to the current marker or delta marker frequency. A signal
can thus be set to as center frequency, for example to examine it in detail with a
smaller span.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:CENTer on page 680
Ref Lvl =Mkr Lvl
Sets the reference level to the current marker level.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:REFerence on page 692
Marker to Trace
Opens an edit dialog box to enter the number of the trace on which the marker is to be
placed.
Remote command:
CALCulate<n>:MARKer<m>:TRACe on page 673
CALCulate<n>:DELTamarker<m>:TRACe on page 625
Min
Sets the active marker/delta marker to the minimum of the selected trace.
Measurement Functions

Table of Contents

Related product manuals