Remote Control
R&S
®
FSVA/FSV
667Operating Manual 1176.7510.02 ─ 09
Parameters:
<State> ON | OFF
*RST: ON
Example:
CALC:MARK:LOEX ON
Manual operation: See "Exclude LO" on page 304
CALCulate<n>:MARKer<m>:MAXimum[:PEAK]
This command positions the marker on the current trace maximum.
The corresponding marker is activated first or switched to the marker mode.
If no maximum value is found on the trace (level spacing to adjacent values < peak
excursion), an execution error (error code: -200) is produced.
In "Spectrogram" mode, this command positions the specified marker on the current
peak level of the x-axis. The search is performed within the current frame. It does not
change the position of the marker on the y-axis.
Suffix:
<n>
.
Selects the measurement window.
<m> depends on mode
Selects the marker.
Example:
CALC:MARK2:MAX
Positions marker 2 to the maximum value of the trace.
Usage: Event
Manual operation: See "Peak" on page 302
See "Marker Search Type" on page 306
CALCulate<n>:MARKer<m>:MAXimum:AUTO <State>
This command turns an automatic marker peak search for a trace maximum on and
off. The command performs the peak search after each sweep.
An automatic peak search may be used during adjustments of a device under test to
keep track of the actual peak marker position and level.
If no maximum value is found on the trace (level spacing to adjacent values < peak
excursion), an execution error (error code: -200) is produced.
Suffix:
<n>
.
Selects the measurement window.
<m> Selects the marker.
Parameters:
<State> ON | OFF
*RST: OFF
Remote Control – Commands