Remote Control
R&S
®
FSVA/FSV
807Operating Manual 1176.7510.02 ─ 09
Manual operation: See "0.1*Span (span > 0)" on page 219
See "0.1*RBW (span > 0)" on page 219
See "0.5*Span (span > 0)" on page 219
See "0.5*RBW (span > 0)" on page 220
[SENSe:]FREQuency:MODE <Mode>
This command selects the frequency mode.
between span > 0 and zero span in the "Spectrum" mode.
Parameters:
<Mode> CW
Selects the time domain (span = 0).
In the time domain, define the measurement frequency with
[SENSe:]FREQuency:CENTer.
FIXed
Selects the time domain (span = 0).
In the time domain, define the measurement frequency with
[SENSe:]FREQuency:CENTer.
SWEep
Selects the frequency domain (span > 0).
In the frequency domain, define the frequency characteristics
with the following commands:
• [SENSe:]FREQuency:STARt
• [SENSe:]FREQuency:STOP
• [SENSe:]FREQuency:SPAN
• [SENSe:]FREQuency:CENTer
*RST:
SWEep
Example:
FREQ:MODE SWE
Selects the frequency domain.
Usage: SCPI confirmed
[SENSe:]FREQuency:OFFSet <Offset>
This command defines the frequency offset.
Parameters:
<Offset> Range: -100 GHz to 100 GHz
*RST: 0 Hz
Default unit: Hz
Example:
FREQ:OFFS 1GHZ
Manual operation: See "Frequency Offset" on page 221
[SENSe:]FREQuency:SPAN <Span>
This command defines the frequency span.
Remote Control – Commands