STEReo:DIRect "EON-TP=<PI>,<TP>"
STEReo:DIRect? "EON-TP,<PI>"
Enhanced Other Networks: Sets the TP flag for the EON with the selected <PI>.
Parameters:
<PI> Range: 0000 to FFFF (ASCII coded hexadecimal num-
bers)
Setting parameters:
<TP> 0 | 1
Example:
STEReo:DIRect "EON-TP=1000,1"
Sets the TP flag for the EON with PI=1000 to "1".
STEReo:DIRect "GS=<Group#1>,<Group#2>,...<Grpup#36>"
STEReo:DIRect? "GS"
Sets or reads the group sequence.
Note: Sends only group A or group B data at a time. Transmits only groups that con-
tain data. The groups 4A, 14B and 15B are automatically added to the group sequence
and must not be added or removed manually.
Setting parameters:
<Group> 0A,1A,2A, … to 15B
Example:
STEReo:DIRect "GS=0A,1B,10A,15A"
The groups 0A, 1B, 10A and 15A are transmitted.
STEReo:DIRect "IMP=<x>"
STEReo:DIRect? "IMP"
(for documentation reasons only)
Sets external L, R impedances.
Use the SCPI command [:SOURce]:STEReo:EXTernal:IMPedance instead.
Setting parameters:
<x> 1 | 2
1
600 Ohms
2
100 kOhm
Example:
STEReo:DIRect "IMP=1"
Sets the external impedance to 600 Ohms.