26. Virtual LANs
ROX™ v2.2 User Guide 267 RuggedBackbone™ RX5000
operate in a VLAN-aware mode while providing functionality required for almost any network application.
However, the IEEE 802.1Q standard defines a set of rules that must be followed by all VLAN-aware
switches:
Valid VID range is 1 to 4094 (VID=0 and VID=4095 are invalid).
Each frame ingressing a VLAN-aware switch is associated with a valid VID.
Each frame egressing a VLAN-aware switch is either untagged or tagged with a valid VID (this means
priority-tagged frames with VID=0 are never sent out by a VLAN-aware switch).
Some applications have requirements conflicting with the IEEE 802.1Q native mode of operation. For
example, some applications explicitly require priority-tagged frames to be received by end devices).
26.1.8. GVRP (GARP VLAN Registration Protocol)
GVRP is a standard protocol built on GARP (the Generic Attribute Registration Protocol) to automatically
distribute VLAN configuration information in a network. Each switch in a network needs only to be
configured with VLANs it requires locally; it dynamically learns the rest of the VLANs configured
elsewhere in the network via GVRP. A GVRP-aware end station, configured for a particular VLAN ID,
can be connected to a trunk on a GVRP-aware switch and automatically become part of the desired
VLAN.
When a switch sends GVRP BPDUs out of all GVRP-enabled ports, GVRP BPDUs advertise all the
VLANs known to that switch (configured manually or learned dynamically through GVRP) to the rest
of the network.
When a GVRP-enabled switch receives a GVRP BPDU advertising a set of VLANs, the receiving port
becomes a member of those advertised VLANs and the switch begins advertising those VLANs via all
the GVRP-enabled ports (other than the port on which the VLANs were learned).
To improve network security using VLANs, GVRP-enabled ports may be configured to prohibit the
learning of any new dynamic VLANs but at the same time be allowed to advertise the VLANs configured
on the switch.

Table of Contents

Other manuals for RuggedCom RUGGEDBACKBONE RX5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RuggedCom RUGGEDBACKBONE RX5000 and is the answer not in the manual?

RuggedCom RUGGEDBACKBONE RX5000 Specifications

General IconGeneral
BrandRuggedCom
ModelRUGGEDBACKBONE RX5000
CategorySwitch
LanguageEnglish

Related product manuals