6. Alarms
ROX™ v2.2 User Guide 91 RuggedBackbone™ RX5000
6.2.2. Chassis Alarm Configuration
Figure 6.11. Chassis Alarm Configuration table
The path to the Chassis Alarm Configuration form is admin/alarm-config/chassis.
Figure 6.12. Chassis Alarm Configuration form
The path to the Chassis Alarm Configuration form is admin/alarm-config/chassis/{alarm id).
id
Synopsis: integer
This is the ID number of the alarm assigned by the system.
description
Synopsis: A string
The name of the alarm.
severity
Synopsis: string - one of the following keywords { debug, info, notice, warning, error, critical,
alert, emergency }
The severity level can be one of emergency, alert, critical, error, warning, notice, info, and debug.
This cannot be changed for some alarms
admin-enable
If disabled, the alarm is not reported in the active list and does not actuate led/failrelay.
failrelay-enable
If enabled, this alarm will assert the failrelay.
led-enable
If enabled, the main 'Alarm' LED light will be red when this alarm is asserted. If disabled, the main
'Alarm' LED light is not affected by this alarm.

Table of Contents

Other manuals for RuggedCom RUGGEDBACKBONE RX5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RuggedCom RUGGEDBACKBONE RX5000 and is the answer not in the manual?

RuggedCom RUGGEDBACKBONE RX5000 Specifications

General IconGeneral
BrandRuggedCom
ModelRUGGEDBACKBONE RX5000
CategorySwitch
LanguageEnglish

Related product manuals