3. Time Synchronization
ROX™ v2.2 User Guide 61 RuggedBackbone™ RX5000
After booting, NTP uses slewing to achieve synchronization by making small and frequent changes to
the router hardware clock. If the reference server’s clock differs from the local clock by more than 1000
seconds, the NTP daemon decides that a major problem has occurred and terminates.
3.2. Configuring Time Synchronization
To configure time synchronization, configure the following items:
set the system time and date. See Section 3.2.1, “Configuring the System Time and Date”.
set the system timezone. See Section 3.2.2, “Configuring the System Time Zone”.
set the local time settings. See Section 3.2.3, “Configuring the Local Time Settings”.
add remote NTP servers. You can add remote NTP servers with or without authentication. See
Section 3.2.4, “Configuring NTP Servers”.
set the NTP server restrictions. See Section 3.2.6, “Configuring NTP Server Restrictions”.
configure an NTP server using Multicast or Broadcast. See Section 3.2.7, “Configuring an NTP Server
using Multicast or Broadcast”.
configure an NTP client using Multicast. See Section 3.2.8, “Configuring an NTP Client using
Multicast”.
configure an NTP client using Broadcast. See Section 3.2.9, “Configuring an NTP Client using
Broadcast”.
After configuring NTP, you can check the status of the NTP service. See Section 3.2.10, “Checking
NTP Status”.
3.2.1. Configuring the System Time and Date
To set the system time and date:
Navigate to admin/set-system-clock.
On the Set New Time and Date form, enter the date in the format YYYY-MM-DD HH:MM:SS.
Figure 3.1. Set new Time and Date form
On the Set clock on target device form, click Perform.
3.2.2. Configuring the System Time Zone
To set the system time zone:
In edit mode, navigate to admin.
On the Timezone form, select a timezone from the list.
The Etc/GMT timezones conform to the POSIX style and have their signs reversed from common
usage. In POSIX style, zones west of GMT have a positive sign; zones east of GMT have a negative
sign.

Table of Contents

Other manuals for RuggedCom RUGGEDBACKBONE RX5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RuggedCom RUGGEDBACKBONE RX5000 and is the answer not in the manual?

RuggedCom RUGGEDBACKBONE RX5000 Specifications

General IconGeneral
BrandRuggedCom
ModelRUGGEDBACKBONE RX5000
CategorySwitch
LanguageEnglish

Related product manuals