EasyManua.ls Logo

Safran VersaSync - Rebooting the System; Notifications

Default Icon
414 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Once you have halted your VersaSync, power must be removed (unplugged) and
reapplied in order to restart the unit.
4.2 Rebooting the System
To reboot VersaSync via the Web UI:
1. Navigate to TOOLS > SYSTEM: Reboot/Halt.
2. Select the Restart after Shutdown box in the Reboot/Halt window.
3. VersaSync will now be rebooted and be accessible again shortly thereafter.
Rebooting via USB Port, Telnet, SSH, SNMP
With a serial connection to the USB port, telnet connection or SSH connection,
type reboot <Enter> to reboot VersaSync.
Reboot is also is available to be performed through an snmpset operation. For
more information on VersaSync commands, see "CLICommands" on page313.
4.3 Notifications
If an event occurs e.g., VersaSync transitions into Holdover, or a short is detected
in the GNSS antenna, VersaSync can automatically notify users that a specific
event has occurred.
In some situations, two events are generated. One event occurs in the transition
to a specified state and then another event occurs when transitioning back to the
original state. Examples of these are losing sync and then regaining sync, or
going into Holdover mode and then going out of Holdover mode. Other situ-
ations may only consist of one event. An example of this situation is switching
from one input reference to another.
Notifications of each event that may occur can be via alarms, via SNMP Traps
being sent to one or more SNMP Managers, via an email being sent to a specified
email recipient, or a combination of the three. The Notifications page allows a
user to configure whether the occurrence of each event automatically triggers an
4.2 Rebooting the System
CHAPTER 4 VersaSync User Manual Rev. 12
233

Table of Contents

Related product manuals