E x a m p l e :
? 15 271 12:45:36.123 S
The example data stream provides the following information:
Sync Status The clock has lost GNSS time sync.
Date Day 271 of year 2015.
Time 12:45:36 UTC time, Standard time is in effect.
5.3.12 Spectracom Format 8
Format 8 includes a time synchronization status character, the four digit year,
day of year, time reflecting Time Zone Offset and DST corrections when enabled.
Format 8 also includes the DST/Standard Time indicator, and the Time Zone Off-
set value. Format 8 data structure is shown below:
E x a m p l e :
CR LF I ^ ^YYYY^ DDD ^ HH:MM:SS ^ D+XX CR LF
or
CR LF I ^ ^YYYY^ DDD ^ HH:MM:SS ^ D-XX CR LF
Where:
CR Carriage Return
LF Line Feed
I Time Sync Status (space, ?, *)
YYYY Four digit year indication
^ Space separator
DDD Day of Year (001-366)
HH Hours (00-23)
: Colon separator
MM Minutes (00-59)
SS Seconds (00-60)
358 VersaSync User Manual