Command Description
testevent Generates SNMP events in the enterprise MIB
tfomget Displays current estimated system time error (TFOM – Time Figure of
Merit)
timeget Displays current system time (time is displayed in the configured
timescale – See
scaleget
command to retrieve the configured
timescale)
timeset Used to manually set the current time (hours, minutes in seconds);
time is entered based on the configured timescale – See
scaleget
command to retrieve the configured timescale
unrestrict Used for clearing access control restrictions to
VersaSync
version Displays the installed main
VersaSync
and timing system software ver-
sions
vlanadd Add a VLAN connection
vlandel Delete a VLAN connection
yearget Displays the current year
yearset Used to set the current year
zeroize Applicable to SAASM-equipped
VersaSync
units only
5.3 Time Code Data Formats
This section describes the different time code data format selections available for
use with VersaSync option cards that accept ASCII data streams as inputs or out-
puts via their RS-485 and RS-232 interfaces.
Supported are formats like NMEA, BBC, Spectracom, GSSIP, and Endrun.
5.3.1 NMEA GGA Message
The GGA Format provides essential fix data which includes 3D location and accur-
acy data.
E x a m p l e m e s s a g e :
$GPGGA,123519.00,4807.038,N,01131.000,E,1,08,0.9,545.4,M,-164.0,M,,,,*47
VersaSync User Manual 319
APPENDIX