Q Time Sync Status [as OUTPUT]
space = Time error is less than time quality flag 1's threshold (TFOM < or = 3)
“.” = Time error has exceeded time quality flag 1's threshold (TFOM = 4)
“*” = Time error has exceeded time quality flag 2's threshold (TFOM = 5)
“#” = Time error has exceeded time quality flag 3's threshold (TFOM = 6)
“?” = Time error has exceeded time quality flag 4's threshold OR a reference source is
unavailable (TFOM >=7)
CR Carriage Return (ASCII Character 13)
LF Line Feed (ASCII Character 10)
The leading edge of the first character (CR) marks the on-time point of the data
stream.
5.3.13.1 Format 9S
Format 9S is a variation of ASCII Format 9 that uses Sysplex compatible fields
indicating sychronization status:
FL_SYNC_SYS_REF_NONE ('X') Never been in sync
FL_SYNC_SYS_REF_YES (' ') In sync with a reference
FL_SYNC_SYS_REF_LOST ('F') Out of sync, lost reference
5.3.14 Spectracom Epsilon Formats
5.3.14.1 Spectracom Epsilon TOD1
This message corresponds to the TOD1 format provided by EPSILON 2S/3S Ser-
ies products on RS232/422 ports.
The structure of this format is as follows:
<space>DD/MM/YYYY<space>HH:MM:SST(CR)(LF)
Length=23 bytes
Where:
<space> separator
DD 2-digit Day of month
</> separator
360 VersaSync User Manual