Table 5-1:
Troubleshooting using the Web UI Status indications
Web UI Page loc-
ation
Current Status Indication Troubleshooting
HOME page, Sys-
tem Status panel,
Status row
SYNC indicator is not
“lit” (not Green).HOLD
indicator is “lit”
(Orange).—OR—
FAULT indicator is
“lit” (Red). Below the
System Status panel
there is an Out of
Sync alarm statement
VersaSync
is in
Holdover
mode—OR—
VersaSync
is
now out of
Time Sync
All available Input References
have been lost. The Reference
Status table on the HOME page
will show the current status of
all inputs (Green is valid and
Red is invalid or not present).
1. Make sure the Input Reference
Priority table still has the
desired reference inputs
Enabled, based on the desired
priority. See
"Configuring
Input Reference Priorities"
on page173
.
2. Make sure the desired input
references are still connected to
the correct input port of
Ver-
saSync
.
3. Verify GNSS antenna install-
ation (if applicable). See
"Troubleshooting GNSS
Reception" on page309
.
VersaSync User Manual 307