CHAPTER 2. MMC Programming
2-170
© SAMSUNG Electronics Co., Ltd.
(Continued)
Timer Name Default Range Unit Description
KMMC LOCK OUT TM 30 10-50 SEC This timer controls the grace period between
programming actions while in a programming
session. The timer automatically returns the
system to secure programming status.
LCR ADVANCE TIME 5 1-250 SEC This timer controls the time before selecting
the next allowable route when a station is
allowed to route advance.
LCR INTER DIGIT 5 1-250 SEC This timer controls the grace period between
dialing valid digits before accessing a trunk.
LONG KEY DETECT 600 0-2500
MSEC
This timer controls the time a key must be held
down before the key press is repeated.
LONG KEY REPEAT 300 0-2500
MSEC
This timer controls the time between repeated
digits on a long key press.
MCL DELAY TIME 4 0-9 SEC This timer controls the time when the system
should start transmitting Authorisation Code
after sending MCL access code (Cable&
Wireless 131 access). Available in UK only.
MS LED ON TIME 5 1-10 SEC This timer controls the duration a Manual
Signaling key will remain on after use.
OFF HOOK RING INT 15 1-250 SEC This timer controls the time between ring
bursts to a user who has a camped-on call.
OHVA ANSWER TIME 10 1-250 SEC This timer controls the time allowed to answer
an OHVA call before automatic rejection.
PAGE TIME OUT 20 1-250 SEC This timer controls the duration of a page
announcement.
PAGE TONE TIME 500 100-2500
MSEC
This timer controls the duration of tone burst
heard over the page prior to the page
announcement.
PARK RECALL TIME 45 0-250 SEC This timer controls how long a call is parked
before recalling to the call park originator.
AP-MMC LOCK TIME 5 1-60 MIN This timer monitors the PCMMC/WebMMC/
Installer activity, drops the link if no action is
created by PCMMC and returns the system
back to secure program status.
PERI UCD REPORT 5 3-99 SEC This timer determines the interval between
periodic UCD reports provided to an SIO port.
POWER DOWN TIME 2000 500-9900
MSEC
This timer monitors the power to the ROM
pack to begin shutdown status.
RECALL
DISCONNECT
2 1-250 MIN This is the time an attendant recall will ring
before being disconnected.