No Code Alarm Name Definition
128 MNF38 Card Active Card Active notification
129 MNF39 MEDIA CARD IN MEDIA CARD IN
130 MNF40 MEDIA CARD
OUT
MEDIA CARD OUT with dismount
MNF41 SYS FAN Stop System FAN Stop alarm
MNF42 SYS FAN Run System FAN Run alarm
- MNG-- Minor Error Minor Fault without Alarm Buffer saving
89 MNG01 Phone
Disconnect
Indicates the Phone is disconnected.
Alarm Data = Tel number or Cx-Syy-Pzz
90 MNG02 Phone Connect Indicates the Phone is connected.
Alarm Data = Tel number or Cx-Syy-Pzz
91 MNG03 Off Hook Alarm Indicates Extension Off Hook Alarm timer has expired.
Alarm Data = Tel number or Cx-Syy-Pzz
92 MNG04 On Hook Indicates the Off Hook Alarm Extension is on hook.
Alarm Data = Tel number or Cx-Syy-Pzz
93 MNG05 MGI Packet Loss Indicates the MGI connection RTP packet loss is more
than 10 %.
Alarm Data = Tel number or Cx-Syy-Pzz
94 MNG06 MGI Packet Delay Indicates the MGI connection RTP packet delay is more
than 500 ms.
Alarm Data = Tel number or Cx-Syy-Pzz
DEFAULT DATA
ALL OFF
ACTION DISPLAY
1)
Press Transfer button and enter 852.
01:MJA01 ACT:OFF
POR Restart
2) Enter desired Alarm Display number. (e.g., 64)
64:MNF01 ACT:OFF
Card Out
Press Volume buttons to select desired option and
press Right Soft button to advance the cursor.
3) To select if the alarm is active, press 1 for YES and 0
64:MNF01 ACT:ON
Card Out
An entry will return the cursor to step 2.
OR
Press Volume buttons to make selection and press
Right Soft button to save and return to step 2.