RF200 system planning
4.3 Installation guidelines
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
57
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
Table 4- 18 Reduction of field data due to metal, range as %: Transponder and RF240R
Reader without
direct
metal influence
Reader on
metal
(metal plate)
Reader flush-
mounted in metal
(all round
20 mm)
1)
on metal, distance 20 mm 95 90 75
flush-mounted in metal;
90 75 70
1)
without metal 100 85 75
flush-mounted in metal;
85 70 65
1)
flush-mounted in metal;
70 55 55
1)
1)
flush-mounted in metal,
70 60 50
1)
without metal 100 90 80
flush-mounted in metal;
90 75 70
1)
flush-mounted in metal,
75 70 50
flush-mounted in metal;
90 60 40
2)
2)
2)
flush-mounted in metal;
70 60 60