6-2-62 ENGINE GENERAL INFORMATION AND DIAGNOSIS (M13 ENGINE)
DTC Confirmation Procedure
1) Clear DTC. Refer to DTC Clearance.
2) Start engine and keep it at idle for 10 seconds.
3) Check DTC. Refer DTC Check.
Troubleshooting
Step Action Yes No
1Was Engine and Emission Control System Check per-
formed?
Go to Step 2. Go to Engine and
Emission Control
System Check in
this section.
2 Check oil control valve power supply circuit.
1) Disconnect connectors from oil control valve with ignition
switch turned OFF.
2) Connect oscilloscope between E22-3 terminal of ECM
connector and engine ground with ignition switch turned
ON.
3) Check waveform of oil control valve referring to Inspection
of ECM and Its Circuits in this section.
Is it in good condition?
Go to Step 3. Go to Step 8.
3 Check wire circuit.
1) Disconnect connectors from ECM with ignition switch
turned OFF.
2) Measure voltage between E22-3 terminal of ECM con-
nector and vehicle body ground.
Is voltage 0 1 V?
Go to Step 4. BLK/YEL wire
shorted to power
supply circuit.
4 Check wire circuit.
1) Disconnect connectors from ECM with ignition switch
turned OFF.
2) Check for proper connection to E22-2 and E22-3 termi-
nals of ECM connector
3) If OK, measure resistance between E22-2 terminal of
ECM connector and vehicle body ground.
Is resistance infinity?
Go to Step 5. GRN or BRN/
YEL wire shorted
to ground circuit.
5 Check wire circuit
1) Measure voltage between E22-2 terminal of ECM con-
nector and engine ground with ignition switch turned ON.
Is voltage 0 1 V?
Go to Step 6 GRN or BRN/
YEL wire shorted
to power supply
circuit.
6 Check wire circuit
1) Turn ignition switch to OFF position.
2) Measure resistance between E22-2 terminal of ECM con-
nector and GRN wire terminal of oil control valve connec-
tor.
Is resistance 1
or less?
Go to Step 7. GRN or BRN/
YEL wire open or
high resistance cir-
cuit.
7 Check oil control valve.
1) Check oil control valve referring to Oil Control Valve
Inspection in Section 6E2.
Is it in good condition?
Substitute a know-
good ECM and
recheck.
Replace oil con-
trol valve.

Table of Contents