EasyManua.ls Logo

Suzuki Wagon R Plus RB310 - TCM Power and Ground Circuit Check

Suzuki Wagon R Plus RB310
846 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7B1-48 AUTOMATIC TRANSAXLE (M13 ENGINE)
Diagnostic Flow Table A-5: TCM Power and Ground Circuit Check
Wiring Diagram
Troubleshooting
1. TCM 3. Ignition switch
2. A/T relay [A]: Terminal arrangement of TCM connector (viewed from harness side)
BLK
BLK
BLK
E13-1
E13-23
E13-6
WHT/RED
GRN
BLK/WHT
+BB
E13-24
WHT/BLU
1
2
3
6
24 23
1
E13
E12
[A]
Step Action Yes No
1 Check TCM Back-up Power Circuit
1) Disconnect TCM connector with ignition
switch OFF.
2) Check for proper connection to TCM at
E13-24 terminal.
3) If OK, check voltage at terminal E13-24 of
disconnected TCM connector.
Is it 10 14 V?
Go to Step 2. WHT/BLU circuit open
or shorted to ground.
2 Check TCM Power Circuit.
1) Disconnect TCM connector with ignition
switch OFF.
2) Check for proper connection to TCM at
E13-6 terminal.
3) If OK, turn ignition switch ON and check
voltage at terminal E13-6 of disconnected
TCM connector.
Is it 10 14 V?
Go to Step 4. Go to Step 3.
3 Check A/T Relay Operation.
Check A/T relay operation referring to A/T
Relay Inspection in this section.
Is check result satisfactory?
WHT/RED, GRN.
BLK/WHT or BLK cir-
cuit for power supply
open.
Replace A/T relay.

Table of Contents

Related product manuals