7B1-178 AUTOMATIC TRANSAXLE (M13 ENGINE)
Available shim thickness
5) Remove differential assembly.
Counter Shaft Bearing Preload
1) After applying A/T fluid to countershaft assembly (1) and dif-
ferential assembly (2), fit them.
2) Install torque converter housing to transaxle case, then
tighten bolts to specified torque.
Tightening torque
Torque converter housing bolt: 33 N·m (3.3 kg-m, 24 lb-ft)
Thickness Identification mark
1.80 mm (0.070 in.) A
1.85 mm (0.072 in.) B
1.90 mm (0.074 in.) C
1.95 mm (0.076 in.) D
2.00 mm (0.078 in.) E
2.05 mm (0.080 in.) F
2.08 mm (0.081 in.) G
2.11 mm (0.083 in.) H
2.14 mm (0.084 in.) J
2.17 mm (0.085 in.) K
2.20 mm (0.087 in.) L
2.23 mm (0.088 in.) M
2.26 mm (0.089 in.) N
2.29 mm (0.090 in.) P
2.32 mm (0.091 in.) Q
2.35 mm (0.092 in.) R
2.40 mm (0.094 in.) S
2.45 mm (0.096 in.) T
2.50 mm (0.098 in.) U
2.55 mm (0.100 in.) V
2.60 mm (0.102 in.) W
2.65 mm (0.104 in.) X
2.70 mm (0.106 in.) Y
NOTE:
Record measured differential side bearing preload,
because it is necessary to adjust counter shaft bearing
preload.