www.dadehpardazan.ir 88594014-15
10.2 List of Parameters
10-13
10
Appendix
Pn008
2
Application Function Select
Sw
itch 8
0000 to 7121 0000 After restart Setup
Pn009
2
Application Function Select
Sw
itch 9
0000 to 0111 0010 After restart Tuning
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Reserved (Do not change.)
Function Selection for Undervoltage
Reference
Section
0 Does not detect undervoltage.
5.2.9
1 Detects warning and limits force by host controller.
2 Detects warning and limits force by Pn424 and Pn425. (Only in the SERVOPACK)
Warning Detection Selection
Reference
Section
0 Detects warning.
9.2.1
1 Does not detect warning (except for A.971).
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.

Reserved (Do not change.)
Current Control Method Selection
Reference
Section
0 Current control method 1
6.8.3
1 Current control method 2
Speed Detection Method Selection
Reference
Section
0 Speed detection 1
6.8.5
1 Speed detection 2
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.


Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGDV SERVOPACK and is the answer not in the manual?

YASKAWA SGDV SERVOPACK Specifications

General IconGeneral
ModelSGDV
TypeSERVOPACK
Control ModesPosition, Speed, Torque
Communication InterfaceMECHATROLINK-II, MECHATROLINK-III, EtherCAT
Protection RatingIP20
Operating Temperature0°C to 55°C
Vibration Resistance5.9 m/s² (0.6G) at 10-60Hz
Shock Resistance49 m/s² (5G)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Regenerative overload, Encoder error