Agilent 5DX Service Guide 3-19
5DX Series 3 Operator Control Console
Procedure
1. If the User Interface is running, select System Access and press Enter, then
select Quit from 5DX and press Enter.
2. Type ma and press Enter.
3. At the Master directory prompt, type shutdown and press Enter.
4. Type loadinit and press Enter.
5. Turn off the Motion Driver Power Supply.
6. Disconnect the input line for the 5DX System main air.
7. Open both sliding access panels.
8. Attach the test leads for the ohmmeter to the test points on the Primary Safety
Interlock Contact Block as shown in Figure 3-16.
Figure 3-16: Primary Safety Interlock
WA R N I NG Mechanical motion can cause severe injury. Turn off the Motion Driver
Power Supply to prevent movement of the XYZ Stage Assembly during this
procedure.
Pin Block
Contact Block
T-10 Torx Scre
Test Points