3. Select the InsertionInsertion in case of Errors/Violations.
Alarms will be inserted continuously.
OffOff: Turns off inserting errors.
ManualManual: Inserts errors in the specified counts if you touch the Error
Insert icon.
Burst / secBurst / sec: Inserts errors in the specified counts in one second
periodic.
Burst / 10 secBurst / 10 sec: Inserts errors in the specified counts in ten second
periodic.
Burst*1E-02Burst*1E-02 to Burst*1E-07Burst*1E-07: Inserts errors of burst length in the
specified rate continuously.
For example, Error burst lengthError burst length is set to 3 and Burst*1E-06Burst*1E-06 is selected,
the three errors will be inserted per one million blocks. The Error
Insert icon shows only status.
4. Touch the Burst lengthBurst length field to set the errors insertion counts.
5. When Insertion is set to ManualManual, Touch the Error Insert icon.